This is likely dependent on the serial hardware that is used, however bps is typically a safe option. Feature: 1 Segment: 1 Option: 4. Strange part here is the baudrate on the panel was in theory set to and minicom set to data was coming through perfectly.
Hence think something particular to my panel that option 3 is ??? Screen shot below from minicom shows the stream of data coming in, having the correct baud rate will show a string of HEX data as opposed to the last line having the incorrect baud rate, displaying garbled characters. We still need to confirm if you can transmit to the panel.
Follow this process to install the py server component:. Follow this process to ensure NX loads on power up:. You can check status of the daemon using: sudo systemctl status nx The PYN server should have discovered all the zones and created a config.
Contents of alarmpanel. Hope that makes sense. HA also uses the zone names as the friendly name. Refer to:. Hope this get you of a bind, if need help send PM and happy to help. Hi Rob. Rob, Thanks for this. Any ideas? Not sure on that one, it simply worked for me. Can you arm or disarm the panel via HA?
Have you run through my suggested steps? After looking at the source code, it looks like home away vs stay is actually dependent on whether zones are bypassed.
Do you know if that is accurate? Noticed it can be also hit and miss to arm the system, sometimes it arms on the first go but typically have to enter the arm code several times before it accepts. Have you experienced this issue? Hi robg. Just a quick note to say thanks heaps for putting the effort in to post this.
System is up and running with relatively little work thanks to your guide. Much appreciated. I have the nx-4 and when I am in programming mode and I press [9]-[1]-[5]-[ ] , nothing happens. Did you turn off AC and disconnect the battery when installing the NX? I have made several attempts connecting the NX Everytime, my control panel does not work properly when the NX is connected.
Will I have better luck turning off the nx-4 and rebooting it? I have installed a caddx NX-8 alarm system with 3 partitions and a NX module. I have connected my RPi3 running home assistant with the NX-8 board via the nx module using a usb-to-serial-rs adapter. At the moment i can communicate with the nx-8 alarm system through home assistant buy I have some issues. The main problem I face is that I can arm the alarm but I cannot disarm it.
In the log file I see the arm activation but there is nothing no error indication when i send the disarm command. Also a second issue I have is that I have included nx as a binary sensor in my configuration. In some parts of the world Caddx sells a cable with these connections. Third-party pin serial cables might have the same pinout. Otherwise you can make one yourself.
Extending the serial line. The Vera and the Alarm panel might not be in the same room. You can add a female-to-male straight DB9 serial cable onto the end to make the serial connection as long as you like. Connecting Vera to the serial line. Zones are not detected automatically, so you must scan for the zones that your alarm system has. It may be necessary to click the tab a second time. To scan for zones, enter the highest-numbered zone in your system into the Maximum zone text box, and click Scan.
The plugin asks the alarm panel for all zones from 1 to the maximum, and if it is supported and you have enabled it , each zone's name. Edit each zone's name and click Add.
On the next Luup engine reload press SAVE on the main window , the new zones will be created as child devices. You can rename and relocate zones to other rooms. If you want to delete a zone, do this from the same Zones tab that you used to add zones. Skip to content. Star 5. Branches Tags.